PW System

Pure water equipment requirements:The water quality meets all the provisions of China pharmacopoeia standard and FDA; Automatic equipment operation and conditional automatic processing program (such as back flush, regeneration, acid-washing and disinfection procedures); Monomer and pipe equipment meet GMP requirements (all such back end processing equipments as sterilizer, membrane filtration, terminal water tank and pipeline adopt the 316L material and the pre-treatment pipeline adopts SUS304 material).

PW System

Water Distiller

S series multi-effect water distiller is designed according to the principle of falling film and multiple-stage evaporation. The first effect is to conduct heating by external heat source (industrial steam), and then each pillar can get enough heat energy by using the pure vapor produced from the fore-effect. The material water that did not evaporate in the first effect can be taken as the material in the next effect, and so on.

Water Distiller

PS Generator

The standard equipment model table shows the production capacity of the units at 3 bar pure steam pressure and 6 bar industrial steam pressure, expressed in kg/h. For certain equipment types, the actual production capacity should be calculated based on the actual operating pressure and multiplied by the specified capacity conversion factor. Regarding utility requirements, the industrial saturated steam must be free of impurities and corrosive substances, with a maximum allowable pressure of 9 bar. The feed water must be deionized water, free from silica, chlorine, amines, and volatile substances, with a required pressure of 1–2 bar. The power supply standard shall be provided according to customer requirements. Compressed air must be dry, oil-free, and clean, with a minimum required pressure of 6 bar.

PS Generator

Preparation System

The Preparation System is designed for material preparation in industries such as bioengineering, large infusions, oral solutions, and fine chemistry. It effectively mitigates the risks of cross-contamination and product contamination during the preparation process, enhancing production efficiency and product reliability.

Preparation System

Fermenter

Fermentation system included: seed tanks, fermentation tanks, controlling system, air handling system, feeding system, piping system, valves, operating platforms, utilities etc. We manufacture the follow-up processing systems for users. Accoding to the requirements of the users, we can design the fermentation workshop and be responsible for on-site installation and commissioning. Our company also trains the employers for the clients and provide the GMP arguments to help users.

Fermenter

< >

PW System

Pure water equipment requirements:The water quality meets all the provisions of China pharmacopoeia standard and FDA; Automatic equipment operation and conditional automatic processing program (such as back flush, regeneration, acid-washing and disinfection procedures); Monomer and pipe equipment meet GMP requirements (all such back end processing equipments as sterilizer, membrane filtration, terminal water tank and pipeline adopt the 316L material and the pre-treatment pipeline adopts SUS304 material).

PW System

Water Distiller

S series multi-effect water distiller is designed according to the principle of falling film and multiple-stage evaporation. The first effect is to conduct heating by external heat source (industrial steam), and then each pillar can get enough heat energy by using the pure vapor produced from the fore-effect. The material water that did not evaporate in the first effect can be taken as the material in the next effect, and so on.

Water Distiller

PS Generator

The standard equipment model table shows the production capacity of the units at 3 bar pure steam pressure and 6 bar industrial steam pressure, expressed in kg/h. For certain equipment types, the actual production capacity should be calculated based on the actual operating pressure and multiplied by the specified capacity conversion factor. Regarding utility requirements, the industrial saturated steam must be free of impurities and corrosive substances, with a maximum allowable pressure of 9 bar. The feed water must be deionized water, free from silica, chlorine, amines, and volatile substances, with a required pressure of 1–2 bar. The power supply standard shall be provided according to customer requirements. Compressed air must be dry, oil-free, and clean, with a minimum required pressure of 6 bar.

PS Generator

Preparation System

The Preparation System is designed for material preparation in industries such as bioengineering, large infusions, oral solutions, and fine chemistry. It effectively mitigates the risks of cross-contamination and product contamination during the preparation process, enhancing production efficiency and product reliability.

Preparation System

Fermenter

Fermentation system included: seed tanks, fermentation tanks, controlling system, air handling system, feeding system, piping system, valves, operating platforms, utilities etc. We manufacture the follow-up processing systems for users. Accoding to the requirements of the users, we can design the fermentation workshop and be responsible for on-site installation and commissioning. Our company also trains the employers for the clients and provide the GMP arguments to help users.

Fermenter

< >